LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2018 >> Focus Electric >> Repair and Diagnosis >> External Pages >> Different car >> Section 404 (Fuel System - General Information - 1.6L DURATEC-16V Ti-VCT (88KW/120PS) - Sigma) >> General Procedures >> Quick Release Coupling

Quick Release Coupling

WARNING: This page is about a different car, the 2018 Ford Fiesta. However, it is still accessible from the selected car via links, so may be relevant.

For information on Ford Color Coded Illustrations refer to OEM Color Coding .

Disconnect 

NOTE: When reusing liquid or vapor tube connections, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE: Type 1 
  1. If servicing a liquid fuel tube quick release coupling, release the fuel system pressure. Refer to: Fuel System Pressure Release .
  2. Disconnect the battery ground cable. Refer to: Battery Disconnect and Connect .
    • Release the locking tabs.

    • Pull up on the clip.

    • Depress the release.

    GFD302068Courtesy of FORD MOTOR COMPANY
  3. Disconnect the quick release coupling from the tube.
GFD302069Courtesy of FORD MOTOR COMPANY

Connect 

  1. Inspect and clean both quick coupling ends. Install the quick release coupling onto the tube until fully seated.
    GFD302070Courtesy of FORD MOTOR COMPANY
  2. NOTE: Make sure the retainer clip is fully seated and locked onto the tube by pulling on the quick connect coupling.

    Press the retainer clip into the quick connect coupling body until flush and the tabs are locked in place.

    GFD302071Courtesy of FORD MOTOR COMPANY
  3. Connect the battery ground cable. Refer to: Battery Disconnect and Connect .

Disconnect 

NOTE: When reusing liquid or vapor tube connections, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE: Type 2 
  1. If servicing a liquid fuel tube quick release coupling, release the fuel system pressure. Refer to: Fuel System Pressure Release .
  2. Disconnect the battery ground cable. Refer to: Battery Disconnect and Connect .
  3. Squeeze the quick release coupling retainer locking tabs to release the locking mechanism and push the locking mechanism outward to release the tube.
    GFD302072Courtesy of FORD MOTOR COMPANY
  4. Remove the quick release coupling from the tube.
GFD302073Courtesy of FORD MOTOR COMPANY

Connect 

  1. Install the quick release coupling onto the tube until fully seated.
    GFD302074Courtesy of FORD MOTOR COMPANY
  2. Depress the quick release coupling locking mechanism into the locked position.
    GFD302075Courtesy of FORD MOTOR COMPANY
  3. Connect the battery ground cable. Refer to: Battery Disconnect and Connect .

Disconnect 

NOTE: When reusing liquid or vapor tube connections, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE: Type 3 
  1. Disconnect the battery ground cable. Refer to: Battery Disconnect and Connect .
  2. Release the locking tab on the quick release coupling and separate from the fitting.
GFD302076Courtesy of FORD MOTOR COMPANY

Connect 

  1. Release the locking tab and install the quick release coupling onto the fitting.
    GFD302077Courtesy of FORD MOTOR COMPANY
  2. Position the locking tab into the locked position.
    GFD302078Courtesy of FORD MOTOR COMPANY
  3. Connect the battery ground cable. Refer to: Battery Disconnect and Connect .

Disconnect 

NOTE: When reusing liquid or vapor tube connections, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE: Type 4 
  1. If servicing a liquid fuel tube quick release coupling, release the fuel system pressure. Refer to: Fuel System Pressure Release .
  2. Disconnect the battery ground cable. Refer to: Battery Disconnect and Connect .
  3. Squeeze the quick release coupling retainer locking tabs to release the locking mechanism and push the locking mechanism outward to release the tube.
    GFD302079Courtesy of FORD MOTOR COMPANY
  4. Remove the quick release coupling from the tube.
GFD302080Courtesy of FORD MOTOR COMPANY

Connect 

  1. Install the quick release coupling onto the tube.
    GFD302081Courtesy of FORD MOTOR COMPANY
  2. Connect the battery ground cable. Refer to: Battery Disconnect and Connect .

Disconnect 

NOTE: When reusing liquid or vapor tube connections, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE: Type 5 
  1. Disconnect the battery ground cable. Refer to: Battery Disconnect and Connect .
  2. Release the locking tab on the quick release coupling and separate from the fitting.
    GFD302082Courtesy of FORD MOTOR COMPANY
  3. Remove the quick release coupling from the tube.
GFD302083Courtesy of FORD MOTOR COMPANY

Connect 

  1. Install the quick release coupling onto the tube.
    GFD302084Courtesy of FORD MOTOR COMPANY
  2. Connect the battery ground cable. Refer to: Battery Disconnect and Connect .