Pinpoint Test
- VERIFY THE DOOR LOCK OPERATION
- Press the lock and unlock button on the driver door lock control switch while observing the door lock operation.
Do the door locks operate correctly?
- Yes: GO to 2 .
- No: CHECK the symptom(s). REFER to Symptom Chart: Handles, Locks, Latches and Entry Systems - Electrical .
- VERIFY THE HAZARD LAMP OPERATION
- Place the hazard switch in the ON position.
Do the hazard lamps operate correctly?
- Yes: GO to 3 .
- No: REFER to DIAGNOSTIC ROUTINE R : One Turn Signal Lamp Is Inoperative Or Always On.
- VERIFY THE LIFTGATE OPERATION
- Press the interior power liftgate switch.
Does the power liftgate open?
- Yes: GO to 4 .
- No: REFER to DIAGNOSTIC ROUTINE A : The Power Liftgate Is Inoperative.
- VERIFY THE HORN OPERATION
- Using the scan tool, view the BCM PIDs .
- Select the BCM PID HORN and active command the horn on.
Does the horn sound when commanded on?
- Yes: GO to 5 .
- No: REFER to DIAGNOSTIC ROUTINE A : The Horn Is Inoperative.
- VERIFY THE REMOTE START BUTTON
- Using the scan tool, view the RFA module PIDs .
- Select the RFA module PID Lst_Xm_B_Prs while pressing the remote start button on an IA key.
Does the PID indicate the remote start button is being pressed?
- Yes: REFER to DIAGNOSTIC ROUTINE F : The Remote Start Is Inoperative.
- No: REPLACE and PROGRAM the inoperative IA key:
REFER to ERASE ALL KEYS AND PROGRAM TWO KEYS ,
REFER to KEY PROGRAMMING USING DIAGNOSTIC EQUIPMENT , or
REFER to KEY PROGRAMMING USING TWO PROGRAMMED KEYS .