Component Testing
WARNING: This page is about a different variant/trim than selected.
- Vehicle OFF, disable the high voltage at the T6 Power Inverter Module. Refer to High Voltage Disabling
.WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure includes the following steps:
- Identify how to disable high voltage.
- Identify how to test for the presence of high voltage.
- Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
- Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.
- Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.
- Visually and functionally inspect the gloves before use.
- Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.
Failure to follow the procedures may result in serious injury or death.
- Verify correct oil pressure by performing the Line Pressure Check .
- If you found a concern, repair the concern.
- Perform the Control Solenoid Valve Performance Test .
- If a concern is found, replace the Q8 control solenoid valve assembly.
- Inspect the valve body assembly for sticking or damaged valves. Refer Control Valve Body Diagnostic Inspection .
- If you found a concern, repair or replace the valve or valve body.
- Inspect the variable high clutch for a stuck On or damaged condition.
- If you found a variable high clutch concern, repair or replace the variable high clutch assembly as necessary.