Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Engine Coolant Temperature Sensor (2) - Install
- Engine Coolant Temperature Sensor Retainer (1) - Install
- Electrical Connector (1) - Connect
- Connect the automatic transmission range selector lever cable (1) to the automatic transmission range selector lever cable lever and automatic transmission range selector lever cable bracket (2). Refer to Range Selector Lever Cable Replacement
- Engine Coolant Air Bleed Hose (3) @ Water Outlet - Connect Engine Coolant Air Bleed Hose Replacement (LKN Radiator Surge Tank to Water Outlet to Exhaust Gas Recirculation Cooler Outlet Pipe)
- Fill the cooling system. Refer to Cooling System Draining and Filling (Static)Cooling System Draining and Filling (GE 47716)
- Intake Manifold Cover - Install Intake Manifold Cover Replacement