Installation Procedure
- Clean the sealing surfaces.
- Install the engine coolant thermostat housing (5) along with a NEW seal ring (1).
- Install the 3 engine coolant thermostat housing bolts (4) and tighten to 8 N.m (71 lb in).CAUTION: Refer to Fastener Caution .
- Install the engine oil cooler outlet hose (3) to the engine coolant thermostat housing.
- Install the engine oil cooler outlet hose clamp (2).
- Connect the engine coolant temperature sensor wiring harness connector.
- Install the radiator outlet hose to the engine coolant thermostat housing. Refer to Radiator Outlet Hose Replacement (1.4L LUV) .
- Connect the positive crankcase ventilation pipe to the turbocharger. Refer to Positive Crankcase Ventilation Hose/Pipe/Tube Replacement .
- Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement .
- Fill the cooling system. Refer to Cooling System Draining and Filling (GE-47716 Fill) and Cooling System Draining and Filling (Static Fill) .