LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Lucerne CX >> Repair and Diagnosis >> External Pages >> Different car >> Section 221 (HVAC Systems - Manual) >> Diagnostic Information and Procedures >> Air Delivery Improper

Air Delivery Improper

WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
Air Delivery Improper

Step Action Yes No
Schematic Reference: HVAC Schematics 
DEFINITION: Air does not flow correctly from the air distribution outlets.
1 Did you perform the Diagnostic System Check - Vehicle? Go to Step 2  Go to Diagnostic System Check - Vehicle in Vehicle DTC Information
2
  1. Turn ON the ignition, with the engine OFF.
  2. Turn OFF the HVAC controls.
Is the blower motor OFF?
Go to Step 3  Go to Blower Motor Always On 
3 Place the blower motor switch in each speed position.
Does the blower motor operate in each speed position?
Go to Step 4  Go to Blower Motor Inoperative 
4 Does the blower motor operate at the desired speeds? Go to Step 5  Go to Blower Motor Malfunction 
5
  1. Place the blower motor switch in the maximum speed position.
  2. Alternately, place mode switch in the Max A/C and Vent positions.
Does the recirculation door move from the recirculation position to the ambient air position?
Go to Step 6  Go to Air Recirculation Malfunction 
6
  1. Install a scan tool.
  2. Recalibrate the HVAC door actuators. Refer to Re-Calibrating Actuators .
  3. With a scan tool, observe the current DTC list in HVAC Systems Automatic.
Does the scan tool display any DTCs?
Go to Diagnostic Trouble Code (DTC) List - Vehicle in Vehicle DTC Information Go to Step 7 
7 Place the mode switch in each mode position.
Does the air flow from the correct air distribution outlets in each selected mode position?
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems Go to Step 8 
8 Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 11  Go to Step 10 
9 Inspect the air distribution system for the following conditions:
  • A restricted passenger compartment air filter
  • An obstruction restricting air flow
  • Air leaks
  • Misaligned ducts

Did you find and correct the condition?
Go to Step 11  -
10 Replace the HVAC control module. Refer to Control Module References in Computer/Integrating Systems for replacement, setup and programming.
Did you complete the replacement?
Go to Step 11  -
11 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3