Blower Motor Malfunction
WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates in at least one, but not all, speed positions. |
|||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 7 | Go to Step 4 |
| 4 |
|
Go to Step 5 | Go to Step 10 |
| 5 |
IMPORTANT:
Place the blower motor switch in the correct speed position for the control circuit that you are testing.
|
Go to Step 8 | Go to Step 6 |
| 6 | Test the suspect blower motor control circuit for an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 9 |
| 7 | Inspect for poor connections at the harness connector of the blower motor assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 11 |
| 8 | Inspect for poor connections at the harness connectors of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 12 |
| 9 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 13 |
| 10 | Repair the battery positive voltage circuit of the blower motor resistor assembly. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 14 | - |
| 11 | Replace the blower motor. Refer to Blower Motor Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
Go to Step 14 | - |
| 12 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
Go to Step 14 | - |
| 13 | Replace the HVAC control module. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup and programming. Did you complete the replacement? |
Go to Step 14 | - |
| 14 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |