Blower Motor Inoperative
WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. |
|||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 6 |
| 4 | Connect a test lamp between the blower motor supply voltage circuit and the ground circuit. Does the test lamp illuminate? |
Go to Step 8 | Go to Step 5 |
| 5 | Test the ground circuit of the blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing
andWiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 15 | Go to Step 9 |
| 6 |
|
Go to Step 9 | Go to Step 7 |
| 7 |
|
Go to Step 10 | Go to Step 11 |
| 8 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections
andConnector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 15 | Go to Step 12 |
| 9 | Inspect for poor connections at the harness connector of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 15 | Go to Step 13 |
| 10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 15 | Go to Step 14 |
| 11 | Repair the ignition 3 voltage circuit of the HVAC control module. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 15 | - |
| 12 | Replace the blower motor. Refer to Blower Motor Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
Go to Step 15 | - |
| 13 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
Go to Step 15 | - |
| 14 | Replace the HVAC control module. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup and programming. Did you complete the replacement? |
Go to Step 15 | - |
| 15 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |