Test Description
WARNING: This page is about a different car, the 2006 Buick LaCrosse and 2006 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 5: The ambient air temperature must be above 3°C (38°F) for this A/C compressor test.
- 6: The specified values are from the A/C System Performance Test.
Too Hot in Vehicle
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted or cooling is insufficient during A/C operation. |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
IMPORTANT:
All DTCs that are set must be diagnosed first unless you were sent to this diagnostic from a specific DTC diagnostic.
|
- | Go to Step 3 | Go to Blower Motor Inoperative |
| 3 | Does the blower motor operate at the desired speeds? | - | Go to Step 4 | Go to Blower Motor Malfunction |
| 4 |
|
- | Go to Step 5 | Go to Air Recirculation Malfunction |
| 5 |
IMPORTANT:
|
- | Go to Step 6 | Go to HVAC Compressor Clutch Does Not Engage |
| 6 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test (LY7)
or Air Conditioning (A/C) System Performance Test (L26)
in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 7 |
| 7 | Inspect the inside air temperature sensor for proper installation. Refer to Inside Air Temperature Sensor Replacement . Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 8 |
| 8 |
|
- | Go to Step 9 | Go to Step 16 |
| 9 |
|
- | Go to Step 10 | Go to Step 13 |
| 10 |
|
220 Counts | Go to Step 11 | Go to Step 18 |
| 11 |
|
- | Go to Step 12 | Go to Step 18 |
| 12 | Test the resistance of the ambient air temperature sensor. Refer to Sensor Resistance Table . Is the resistance near the value in the Sensor Resistance Table? |
- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 14 |
| 13 | Test the resistance of the inside air temperature sensor. Refer to Sensor Resistance Table . Is the resistance near the value in the Sensor Resistance Table? |
- | Go to Step 19 | Go to Step 17 |
| 14 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 16 |
| 15 | Inspect the aspirator tube for an air leak or obstruction. Did you find and correct the condition? |
- | Go to Step 24 | - |
| 16 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 22 |
| 17 | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 20 |
| 18 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 21 |
| 19 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 24 | Go to Step 23 |
| 20 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? |
- | Go to Step 24 | - |
| 21 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? |
- | Go to Step 24 | - |
| 22 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement . Did you complete the replacement? |
- | Go to Step 24 | - |
| 23 | Replace the HVAC control module. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup and programming. Did you complete the replacement? |
- | Go to Step 24 | - |
| 24 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |