Blower Motor Inoperative
WARNING: This page is about a different car, the 2006 Buick LaCrosse and 2006 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
- | Go to Blower Motor Malfunction | Go to Step 3 |
| 3 |
|
- | Go to Step 9 | Go to Step 4 |
| 4 | Test the battery positive voltage circuit of the blower motor control processor for an open, a high resistance or a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 5 |
| 5 | Test the ground circuit of the blower motor control processor for an open or a high resistance. Refer to Circuit Testing
andWiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 6 |
| 6 |
IMPORTANT:
Ensure that the blower motor control processor connector and the HVAC control module connectors are connected during this step in order to avoid misdiagnosis.
|
5 V OFF 1 V ON |
Go to Step 10 | Go to Step 7 |
| 7 |
|
5 V | Go to Step 11 | Go to Step 8 |
| 8 | Test the blower motor speed control circuit of the HVAC control module for an open, short to ground or short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 10 |
| 9 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections
andConnector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 12 |
| 10 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 13 |
| 11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 14 |
| 12 | Replace the blower motor. Refer to Blower Motor Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
- | Go to Step 15 | - |
| 13 | Replace the blower motor control processor. Refer to Blower Control Module Replacement
. Did you complete the replacement? |
- | Go to Step 15 | - |
| 14 | Replace the HVAC control module. Refer to HVAC Control Module Replacement in Computer/Integrating Systems for replacement, setup and programming. Did you complete the replacement? |
- | Go to Step 15 | - |
| 15 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |