Install catalytic converter
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2025 BMW X4, 2024 BMW X4, 2023 BMW X4, 2022 BMW X4, and 2021 BMW X4. However, it is still accessible from the selected car via links, so may be relevant.
- Replace seal (1) on catalytic converter.
Parts: Gasket
- Replace the V-clip (1).
Parts: V-band clamp
- Feed in and install catalytic converter (3).
- Feed in and install the new V-ribbon clip (2).
- Hand-tighten the bolt (1).
- Insert and install the holder (4).
- Tighten down screws (3).
TIGHTENING TORQUE SPECIFICATIONS
| Holder, catalytic conv. to transmission | ||
| M12x100 | Tightening torque | 66 Nm |
- Replace nut (1).
Parts: Nut
- Tighten nut (1).
TIGHTENING TORQUE SPECIFICATIONS
| Catalytic converter/Gasoline particulate filter to holder | ||
| M8x20/M8 nut Replace screw/nut. |
Tightening torque | 19 Nm |
- Replace the screw (2).
Parts: Screw.
- Tighten down screw (2).
TIGHTENING TORQUE SPECIFICATIONS
| Catalytic converter/Gasoline particulate filter to holder | ||
| M8x20/M8 nut Replace screw/nut. |
Tightening torque | 19 Nm |
- Feed in the positive battery cable (1) and attach to clamps (2).
- Tighten the screw (1) on the V-ribbon clip.
TIGHTENING TORQUE SPECIFICATIONS
| Catalytic converter/gasoline particulate filter to exhaust turbocharger | ||
| V-band clamp Replace V-band clamp. |
Tightening torque | 13 Nm |
If installed: Installing differential pressure sensor
Installing differential pressure sensor
- Feed in and install the differential pressure sensor (4).
- Tighten nut (3).
TIGHTENING TORQUE SPECIFICATIONS
| Differential pressure sensor to holder | ||
| hexagon nut M6 | Tightening torque | 8 Nm |
- Replace pressure hose (2)
Parts: Pressure hose
- Push the pressure hose (2) onto the differential pressure sensor (4) in the arrow direction all the way to the stop.
- Connect and lock the connector (1).
The connector (1) must engage audibly.
Follow-up work
- Refer to INSTALLING EXHAUST SYSTEM .
- Refer to INSTALLING THE CONNECTING SUPPORTS ON THE TUNNEL .
- Refer to INSTALLING TANK COVER ON LEFT AND RIGHT .
- Refer to INSTALLING THE OXYGEN SENSOR MONITOR .
- Refer to INSTALLING LAMBDA OXYGEN SENSOR .
- Refer to INSTALLING ACOUSTIC COVER .