Installing both solenoid valves on the right
NOTE:
TECHNICAL INFORMATION
Cleanliness is imperative for the removal or installation of solenoid valves.
Possible malfunctions if valves are contaminated are as follows:
Cleanliness is imperative for the removal or installation of solenoid valves.
Possible malfunctions if valves are contaminated are as follows:
- Rough engine running
- Fault memory entry
- Faulty emission values
- Low engine power
NOTE:
TECHNICAL INFORMATION
Do not clean solenoid valves with compressed air because this may damage the solenoid valves.
Do not clean solenoid valves with compressed air because this may damage the solenoid valves.
- Check the strainer (arrow) for contamination.
- Replace the O-rings (1)
and (2)
.
Parts: O-rings
- Coat the O-rings with motor oil.
- If applicable, fasten the holder of the right pressure converter.
Removing the strainer
NOTE:
TECHNICAL INFORMATION
If a strainer is clogged with dirt, it must be removed.
If a strainer is clogged with dirt, it must be removed.
NOTE:
The description is provided only at one component. The procedure is the same for all other components.
- Release the strainer (1)
at the contact edges (arrows).
- Bend up the spot-welds on the strainer (1) with a screwdriver (2) in arrow direction, until the spot welds open.
- Remove and dispose of the strainer (1)
.
- Avoid damage to the solenoid valve housing such as notches or scratches (see arrows).
NOTE:
TECHNICAL INFORMATION
Incorrect assembly is possible. Ensure correct installation position.
Incorrect assembly is possible. Ensure correct installation position.
- Carefully insert solenoid valves (2) and (5) up to the stop.
- Tighten down screws (3) and (4) .
TIGHTENING TORQUE SPECIFICATIONS
| Holder of solenoid valve to cylinder head | ||
|---|---|---|
| M6 | Tightening torque | 10 Nm |
- Attach and lock connectors (1) and (6) .
Follow-up work
- Refer to INSTALLING THE COOLANT EXPANSION TANK FOR THE LOW-TEMPERATURE COOLANT CIRCUIT .
- Refer to INSTALLING RIGHT AIR DUCT .
- Refer to INSTALLING THE CENTER TOP CROSS CONNECTION .
- Refer to INSTALLING RIGHT INTAKE SILENCER HOUSING .
- Refer to INSTALLING ACOUSTIC COVER .