13 53 318 Remove and install all injectors in the injection system: Notes

WARNING: This page is about a different car, the 2018 BMW 340i, 2017 BMW 340i, and 2016 BMW 340i. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Working on 12 V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
  • Detach battery ground lead from battery.
  • For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
WARNING: Working on fuel system. 
Risk of fire! Danger of explosion! 
  • When working on the fuel system, make sure that the workbay is sufficiently ventilated, e.g. using extraction unit.
  • Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
  • No fire, sparks, open flames or smoking.
CAUTION: On releasing high pressure line, fuel may emerge at high speed. 
Injury hazard! 
  • Wear suitable personal protective equipment.
  • Before performing any installation work, allow cooling system to cool down to less than 40 °C.
  • Note warnings on cylinder head cover.
NOTE: RISK OF DAMAGE 
Damage to the ignition coil. 
The silicone hose of the ignition coil must not be contaminated by fuel as this can lead to failure of the ignition coil. 
  • When working on the fuel system, cover the ignition coils with suitable materials and remove where required.
  • Do not oil or grease the silicone tube of the spark plug socket. The silicone tube is coated with talcum powder to reduce the pulling forces.
NOTE: RISK OF DAMAGE 
Contaminant or foreign body. 
Contamination can result in malfunctions, loss of function or leaks. 
  • Adhere to the utmost cleanliness.
  • Protect components from contamination e.g. by covering.
  • Close off line connections with seal plugs.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.

Preliminary work 