Reducing Agent Tank, Removing And Installing: Removing
Follow all safety precautions, refer to SCR SYSTEM SAFETY PRECAUTIONS .
Follow the guidelines for clean working conditions, refer to CLEAN WORKING CONDITIONS .
Danger due to reducing agent leaking out.
- To prevent large amounts of reducing agent from leaking out when opening the metering line, wait for the recirculation process to complete, refer to SCR SYSTEM SAFETY PRECAUTIONS => Reducing Agent, Automatic Regeneration .
-- Draining the reducing agent tank, refer to REDUCING AGENT TANK, DRAINING .
-- Remove the bolts -arrows- and remove the heat shield -1-.
The reducing agent can cause skin irritation.
- Avoid contact with skin and eyes! Always wear protective gloves and safety glasses.
- If reducing agent should get on your skin, wash it off immediately with soap and water.
- If reducing agent gets in your eye, rinse the eye for several minutes with water.
- Never inhale or swallow the reducing agent!
- Should you swallow any reducing agent, rinse your mouth, drink plenty of water and contact a doctor immediately.
-- Disconnect the connectors -2 and 3- and free up the wiring harness.
-- Disconnect and free up the reducing agent hose -1-, refer to REDUCING AGENT DELIVERY LINE, REMOVING AND INSTALLING .
Risk of accident due to the weight of the tank.
- The tank must be empty when removing it.
-- Place the Engine and Gearbox Jack VAS6931 with a soft foam pad in-between to support the tank.
-- With a second mechanic to hold the tank, remove bolts -arrow-.
For better illustration the tank is shown without the engine and transmission.
-- While guiding the tank by hand, lower the it approximately 100 mm with the Engine and Gearbox Jack VAS6931.
To catch escaping reducing agent place a clean cloth under the separation point.
-- Disconnect the filling hose -1- and the ventilation line -2- by pressing the release button.
-- Seal the open lines and connections with clean plugs from the Engine Bung Set VAS6122.
-- Lower the tank again using the Engine and Gearbox Jack VAS6931. Guide the tank with one hand while lowering it.