Reducing Agent Delivery Module, Removing And Installing: Installing
- Tightening specifications, refer to OVERVIEW - REDUCING AGENT DELIVERY MODULE .
Replace the seal.
Thoroughly clean the sealing ring surfaces.
-- Install the heating reservoir -2- in the tank. Slide the heating element through the gap between the heating reservoir and installation opening into the tank.
-- Stretch the new sealing ring -1- over the heating reservoir and place it on the installation opening.
- The sealing ring must not be twisted on itself.
-- Bring the heating reservoir into the installation position:
- The connector for the reducing agent line -arrow A- must be flush with the installation markings (square depression) -arrow B- on the reducing agent tank.
-- Install the union nut -2- so that the marking -3- lines up at the beginning of the first thread -4-. The arrow marking -1- on the tank is found here.
-- First tighten the union unit by hand, then tighten it using the Key T40283 for a total of 5 /4 turns (450°).
- The marking -3- on the union nut -2- must align with the marking -1- (the arrow lines up with the lines on the side).
Install in reverse order of removal. Note the following:
-- Install the reducing agent tank, refer to REDUCING AGENT TANK, REMOVING AND INSTALLING .
-- Adapting adaptation value after draining reducing agent or replacing components, refer to SELECTIVE CATALYTIC REDUCTION- ADAPTATION VALUE, RESETTING .