Empty used oil container
WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
Protective eye wear must be worn for all procedures!
- Place suitable container for collecting used oil near used oil container - 8 -.
- Connect connecting hose - 2 - to used oil container - 8 - and keep free end in collection container.
- Close valve - 4 - (lever perpendicular to direction of flow).
- Attach valve - 4 - to used oil container - 8 -.
- Connect pressure reducer - 5 - to valve - 4 -.
- Pull out rotary knob at pressure reducer - 5 - and turn left to stop.
- Connect compressed air connector to pressure reducer - 5 -.
- Adjust pressure to 0.1 bar.
- Slowly open valve - 4 - and press oil out of used oil container - 8 - as completely as possible.
- Close valve - 4 -.
- Turn pressure reducer - 5 - back to 0 bar.
NOTE:
- A small quantity of remaining oil is permitted.
- An empty used oil container is necessary for the next step, "evacuation" !
Suctioning oil from damper and line, evacuating and filling
Procedure is described for front axle, same procedure applies to rear axle.
CAUTION:
Protective eye wear must be worn for all procedures!
NOTE:
- Fill new oil container ahead of time Fill new oil container
- Empty used oil container ahead of time Empty used oil container
Suctioning:
- Remove plastic cover - 1 -.
NOTE:
- To attach or detach adapter V.A.S 6209/1 , system line must be locked at central valve to limit the quantity of oil leaked to a minimum and to prevent pressurized central valve from emptying.
- Allocation of central valves and wiring harnesses → Central valve and connections to suspension struts
- Loosen lock nut - 1 - on line to be suctioned, screw in shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
- Connect adapter V.A.S 6209/1 to line to be suctioned.
- Secure pressure gauge - 6 - with chain to vehicle in an appropriate place and connect filler hose to new oil container - 9 -.
- Connect adapter V.A.S 6209/1 , item - 1 - in illustration, to pressure gauge - 6 -.
- Connect connecting hose - 2 - to pressure gauge - 6 - and connect free end to used oil container - 8 -.
- Attach valve - 4 - to used oil container - 8 - , valve closed.
- Connect venturi - 3 - to valve - 4 -.
- Adjust valve as follows:
- A - = Open (lever longitudinal to direction of flow)
- B - = Closed (lever perpendicular to direction of flow)
- C - = Open (lever longitudinal to direction of flow)
- D - = Closed (lever perpendicular to direction of flow)
- Connect compressed air hose to venturi - 3 -.
- Slowly open valve - 4 - at used oil container completely.
Oil is suctioned.
- Open line connection - 1 - at strut approx. one turn and suction oil out until as little remains as possible.
- To shorten suction process, valve - D - should be quickly and regularly opened lightly and closed again immediately during the suction process.
- Perform suction procedure until there is no more oil in connecting hose - 2 -.
- Close line connection - 1 - to strut again.
Evacuating:
"Suctioning" step must be performed.
- Create a vacuum of at least -0.9 bar at pressure gauge - 6 -.
- Continue evacuation process at minimum -0.9 bar for at least 2 minutes.
- Bleed pressure gauge filler line - 6 -.
NOTE:
- During the evacuation process, only open valve lightly - B - and allow oil to be suctioned without bubbles from new oil container - 9 - to pressure gauge.
- Close valve - C -.
- Close valve - 4 -.
- Disconnect compressed air line.
- Perform leak test.
NOTE:
- Vacuum must remain stable at -0.9 bar for at least 2 minutes.
Filling
NOTE:
- "Evacuating" step must be performed.
- Vacuum must be created for "evacuating" step.
- Valve - A - is open.
- Valves - B - to - D - are closed.
- Connect compressed air connector to pressure reducer - 5 -.
- Close pressure reducer completely.
Display 0 bar
- Place pressure reducer - 5 - together with connected compressed air connection on new oil container - 9 -.
- Set pressure reducer to 2 bar.
- Valve - B - open.
Oil flows out of new oil container - 9 - into connected component. Recognizable with decreasing oil level in new oil container.
- Slowly increase pressure at pressure reducer - 5 - to 5 bar.
NOTE:
- At this point, read pressure only at pressure gauge - 6 - , not at pressure reducer.
Component is filled.
- Close valve - A -.
- Close valve - B -.
- Close pressure reducer - 5 - (pull out rotary knob on pressure reducer - 5 - and turn it left to stop).
- Remove adapter V.A.S 6209/1 from vehicle.
- Loosen lock nut - 1 - on filled line, unscrew shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
- After filling process, perform pressure check on respective DRC line → DRC II system pressure check