DRC II system pressure check
WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Special tools, testers and auxiliary items required
- Charging device V.A.S 6209/2
- Hand vacuum pump VAS 6213
Bleed charging device V.A.S 6209/2
Use only approved oil for the bleeding process.
NOTE:
- Charging device V.A.S 6209/2 must always be bled at initial use.
- If charging device V.A.S 6209/2 still shows a pressure greater than 0.5 bar (e.g. from a previous reading), bleeding must not be done.
- To bleed pressure gauge - B - and line section - A - , install special tool as shown in illustration.
NOTE:
- Illustration shows bleeding process by extracting hydraulic oil with hand vacuum pump VAS 6213
- Bleed process must be performed until air bubbles are no longer visible in hose - C -.
- Disconnect hose - C - and - D - and perform system pressure check.
System pressure check is performed on front strut of respective DRC line.
NOTE:
- To attach or detach charging device V.A.S 6209/2 , system line to be checked must be locked at central valve to limit the quantity of oil leaked to a minimum and to prevent pressurized central valve from emptying.
- Remove wheel.
- Remove plastic cover - 1 -.
- Loosen lock nut - 1 - on line to be checked, screw in shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
- Remove dust cap and connect charging device V.A.S 6209/2.
- Loosen lock nut - 1 - on line to be checked, unscrew shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
- Read system pressure at charging device V.A.S 6209/2.
NOTE:
- Pressure increase at charging device V.A.S 6209/2 occurs slowly and takes approx. 2 minutes. DRC system pressure can only be read when V.A.S 6209/2 needle has finally come to a stop.
- Loosen lock nut - 1 - on line to be checked, screw in shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
- Disconnect charging device V.A.S 6209/2 and install dust cap.
- Loosen lock nut - 1 - on line to be checked, unscrew shut-off screw - 2 - until it is hand tight and lock nut - 1 - again.
NOTE:
- Small oil leak which results from connecting or disconnected charging device V.A.S 6209/2 at connection is not critical. Avoid repeating measurements because a small quantity of oil is removed from the system every time V.A.S 6209/2 is connected. Every connection results in a pressure decrease of approx. 0.3 bar from the previous reading. In this way, multiple repeats of measurements cause pressure to fall below minimum level or malfunction.
- If pressure is not OK, determine cause of malfunction and service system.
- Install plastic cover - 1 -.
DRC system pressure values
Pressure values are based on a reference temperature of 20°C.
- 16 bar = maximum pressure
- 15 - 16 bar = Central valve new or in like new condition
- 12 - 15 bar = Normal range of operation, system OK
- 12 bar = System leaking or not filled completely, air entering system, central valve faulty.