Adaptation for comfort system data-BUS
NOTE:
- The adaptation values of the table in ADAPTATION FOR INFORMATION DATA-BUS are input.
- Observe notes when replacing instrument cluster. See REPLACEMENT OF INSTRUMENT CLUSTER, INPUT VALUES .
Indicated on display
Fig 1: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (1 Of 9)
- Press -1 - and -0- and confirm by pressing the -Q- button.
Indicated on display
Fig 2: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (2 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 3: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (3 Of 9)
- Press buttons 6- and 1-.
- Press -Q- button to confirm input.
Indicated on display
Fig 4: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (4 Of 9)
- Press --> button.
Indicated on display
Fig 5: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (5 Of 9)
- Using table in ADAPTATION FOR INFORMATION DATA-BUS , input desired value using scan tool keypad, filling initial positions with "0".
for example desired input value: 768 with tire pressure control
Keypad input: 00768
Indicated on display
Fig 6: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (6 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 7: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (7 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 8: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (8 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 9: VAG 1551 Scan Tool Display - Adaptation For Comfort System Data-BUS, Instrument Cluster With Maintenance Interval Extension (9 Of 9)
- Conclude adaptation of comfort system data-BUS by pressing the -->button.
Table:
EQUIPMENT ADAPTATION VALUE (ADAPTATION FOR COMFORT SYSTEM DATA-BUS)
| Equipment | Adaptation value |
|---|---|
| Instrument cluster | 256 |
| Tire pressure | 512 |
| Parking assistance | 16384 |
| Auxiliary heater | 32768 |
Installed control modules that participate in the comfort system data-BUS (MEASURING VALUE BLOCK 130 Figure ) are added.
NOTE:
The instrument cluster, which supports CAN, is not indicated in the measuring value block, but must be added anyway.
Example: Tire pressure control
- Instrument cluster + tire pressure = 256 + 512 = 768