Adaptation for information data-BUS
NOTE:
- The adaptation values of the table in REPLACEMENT OF INSTRUMENT CLUSTER, INPUT VALUES are input.
- Observe notes when replacing instrument cluster. See REPLACEMENT OF INSTRUMENT CLUSTER, INPUT VALUES .
Indicated on display
Fig 1: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (1 Of 9)
- Press -1 - and -0- and confirm by pressing the -Q- button.
Indicated on display
Fig 2: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (2 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 3: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (3 Of 9)
- Press buttons -6- and -2-.
- Press -Q- button to confirm input.
Indicated on display
Fig 4: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (4 Of 9)
- Press --> button.
Indicated on display
Fig 5: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (5 Of 9)
- Using table in REPLACEMENT OF INSTRUMENT CLUSTER, INPUT VALUES , input desired value using scan tool keypad, filling initial positions with "0".
for example desired input value: 5 Navigation system III (NS-Low) with radio (Symphony)
Keypad input: 00005
Indicated on display
Fig 6: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (6 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 7: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (7 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 8: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (8 Of 9)
- Press -Q- button to confirm input.
Indicated on display
Fig 9: VAG 1551 Scan Tool Display - Adaptation For Information Data-BUS, Instrument Cluster With Maintenance Interval Extension (9 Of 9)
- Conclude adaptation of information data-BUS by pressing the --> button.
Table:
EQUIPMENT ADAPTATION VALUE (ADAPTATION FOR INFORMATION DATA-BUS)
| Equipment | Adaptation value |
|---|---|
| Navigation | 4 |
| No Navigation | 0 |
Installed control modules that participate in the information system data-BUS (MEASURING VALUE BLOCK 140 ) are added.