Instrument cluster with maintenance interval extension (MIE), On Board Diagnostic (OBD): Adaptation: Notes
Individual functions are called up by entering the appropriate adaptation channel numbers (listed in the adaptation table under INITIATING "ADAPTATION" FUNCTION 10 ).
NOTE:
- Using measuring value blocks 10, 11, 12, 15 and 16, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42, 43, and 44 (see MEASURING VALUE BLOCK 13 and MEASURING VALUE BLOCK 14 ) must be adapted according to the oil quality (see MEASURING VALUE BLOCK 15 .
- Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system.
- MEASURING VALUE BLOCK 125 and MEASURING VALUE BLOCK 126 indicate the components that are part of the powertrain data-BUS.
- MEASURING VALUE BLOCK 130 indicates the components that are part of the comfort system data-BUS.
- MEASURING VALUE BLOCK 140 indicates the components that are part of the information data-BUS.