Adaptation channel 44 - maximum time interval

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2005 Audi allroad, 2004 Audi allroad, 2004 Audi A6, 2003 Audi allroad, and 2003 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.

This function is used to set a fixed maximum time in days in the instrument cluster for the SRI.

Display on VAS 5051:

Fig 1: Display On VAS 5051 - Adaptation Channel 44, Maximum Time Interval (1 Of 3)
G02720589Courtesy of AUDI OF AMERICA, INC.

Display on VAS 5051:

Fig 2: Display On VAS 5051 - Adaptation Channel 44, Maximum Time Interval (2 Of 3)
G02720590Courtesy of AUDI OF AMERICA, INC.
  1. Channel 44
    1. read and test
  2. Maximum value In spec. in 1 Days
  3. Keypad - only direct input via the keypad is possible
  4. The sliding bar is positioned on the current adaptation value, e.g. 365

    The display indicates the maximum time interval in days to the next service (here for example, 365 represents 365 days).

NOTE:
  • The currently valid specifications can be found in the "Maintenance" book.

    See MAINTENANCE .

  • Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.

Example:

Specification: for example 365 days

Keypad input: 00365

NOTE: The "Save" button does not appear if an incorrect value was entered!

Display on VAS 5051 after performed adaptation:

Fig 3: Display On VAS 5051 - Adaptation Channel 44, Maximum Time Interval (3 Of 3)
G02720591Courtesy of AUDI OF AMERICA, INC.
  1. Channel 44
    1. Value 365 stored