B - Change adaptation value via direct input:
WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2005 Audi allroad, 2004 Audi allroad, 2004 Audi A6, 2003 Audi allroad, and 2003 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.
Display on VAS 5051:
Fig 1: VAS 5051 Tester Display - Changing Adaptation Value Via Direct Input (Instrument Cluster) (1 Of 4)
- Press "Keypad" button -3-.
Display on VAS 5051:
Fig 2: VAS 5051 Tester Display - Changing Adaptation Value Via Direct Input (Instrument Cluster) (2 Of 4)
- Enter adaptation value Input value: 0 to 65535
- Enter 5-digit adaptation value in button field -2-. If necessary, insert zeros in front.
Example:
Desired input value: 1
Keypad input: 00001
- Press -Q- button to confirm input.
Display on VAS 5051:
Fig 3: VAS 5051 Tester Display - Changing Adaptation Value Via Direct Input (Instrument Cluster) (3 Of 4)
- 1 - Channel X save
- 2 - Text display of selected channel or No indication
- 4 - original value X new value X
- Confirm new adaptation value by pressing the "take over" button -3-.
Display on VAS 5051:
Fig 4: VAS 5051 Tester Display - Changing Adaptation Value Via Direct Input (Instrument Cluster) (4 Of 4)
- Channel X Value X stored
- End function "10 - Adaptation" by pressing <-- button.