Adaptation channel 41 - time since service
WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2005 Audi allroad, 2004 Audi allroad, 2004 Audi A6, 2003 Audi allroad, and 2003 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.
This function is used to input the time in days since the last service.
Display on VAS 5051:
- Select function "41" in button field -2- for "Adaptation channel 41" and press Q button to confirm input.
Display on VAS 5051:
- Channel 41
read and test
- Actual value In spec. in 1 Days
- Keypad - only direct input via the keypad is possible
- The sliding bar is positioned on the current adaptation value, e.g. 110 Time in days since last service is displayed (here for example 110 represents 110 days)
NOTE:
- Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
- When replacing instrument cluster, observe. See Input values for replacing instrument cluster .
- Change adaptation value via direct input. See B - Change adaptation value via direct input: .
- Enter 5-digit adaptation value. Insert zeros in front.
Example:
Desired input value: for example 200 days
Keypad input: 00200
Display on VAS 5051 after performed adaptation:
- Channel 41
Value 200 stored
- End function "10 - Adaptation" by pressing <= button.