System test
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2003 Audi S8, 2003 Audi A8, 2002 Audi S8, 2002 Audi A8, and 2001 Audi S8. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
After every Login-Procedure, the Immobilizer unit is disabled for 5 minutes if the ignition key is removed. Therefore carrying out the System Test during this time is not recommended.
- Ignition must be OFF for a minimum of 5 minutes.
- Cover the read coil with a metal plate with a hole, for example, a properly sized washer. Place the washer on to the ignition lock and insert the ignition key true the hole into the ignition lock.
- Disconnect electrical wire to the reader coil at the plug between the ignition switch and the control module for the Immobilizer unit.
- Start the engine.
or
- The engine must not be running and the control light must be blinking.
- Initiate OBD of immobilizer. See ANTI-THEFT IMMOBILIZER ON BOARD DIAGNOSTIC (OBD), INITIATING .
- Check DTC Memory. See CHECK DTC MEMORY (FUNCTION 02)
.
One of the two error codes is displayed on display unit.
Indicated on display
or
Indicated on display
- Erase DTC memory. See ERASE DTC MEMORY (FUNCTION 05) .
- End Output. See END OUTPUT (FUNCTION 06) .