Checking Component And Wiring
- Ignition off
- Light switch in position 0
- Disconnect connector A from the left-hand gas discharge lamp module (GDL).
Check the connectors for contact resistance and oxidation. Check for damage carefully.
Remedy as necessary.
Other information:
Was a fault detected?
- YES
Refer to VERIFICATION
- NO
Refer to CHECKING COMPONENT