Checking the wiring and component
- Ignition off
- Open the control system.
Check the cable between transmission connector terminal #C3 (transmission side) and the connector for solenoid S3. Check for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Check solenoid S3 by measuring the resistance between the terminal pin on solenoid S3 and the transmission housing. The resistance must be 11-15 Ω.
Remedy as necessary.
Other information:
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting / connecting
- To open the control system and to check or replace solenoid S3, see Solenoid control system, replacing
- To replace the cable harness for the control system, see Wiring harness / oil temperature sensor, replacing
- For information about signals, see Signal description. Transmission control module (TCM) .
- Continue
Refer to Resetting the adaptation