Checking the connectors and cables
The blower fan motor power unit is very sensitive to short-circuits and excess current. Do not damage the power unit when taking readings.
Take readings with the power unit connector disconnected when checking the wiring.
Check the connectors on the control module (terminals #A2, #A3) and the power unit. Check for contact resistance and oxidation. Check for loose connections.
Check the ground lead between the power unit terminal #A4 and the ground terminal. Check for an intermittent short-circuit to supply voltage.
Check the control signal cable between the control module terminal #A3 and power unit terminal #A1. Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground.
Check the diagnostic signal cable between control module terminal #A2 and power unit terminal #A3. Check for an intermittent short-circuit to supply voltage.
If the battery voltage has been interrupted, the blower fan speed must be calibrated. First turn the blower fan speed control to maximum speed and then to minimum speed.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To access and replace the control module, see Dashboard environment panel (including climate control module (CCM)), replacing
- To access or replace the power unit, see Blower fan motor / power unit, replacing
- For other values, see Signal specification
- See Checking wiring and terminals .