Checking components and wiring
Check the cable between control module terminal #B3 (#3) and air quality sensor terminal #3. Check for an open-circuit. Check for a short-circuit to supply voltage.
Check the cable between control module terminal #B5 (#5) and air quality sensor terminal #5. Check for an open-circuit. Check for a short-circuit to supply voltage.
Check the cable between control module terminal #B16 (#16) and air quality sensor terminal #1. Check for an open-circuit. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access and replace the control module see Dashboard environment panel (including climate control module (CCM)), replacing
- -2001 see Replacing the air quality sensor
- 2002- see Replacing the air quality sensor .
- For other values, see Signal description, climate control module (CCM), Connector B
- See Checking wiring and terminals .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Information