Checking components and wiring - Electronic climate control
Check the damper motor connector and the climate control module connector B for contact resistance and oxidation according to Contact resistance and oxidation .
Check the power cable between the damper motors and the climate control module for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .
- #3 to #B11
- #4 to #B12
- #5 to #B13
- #6 to #B14
Check the signal cable (#1) between the damper motors and climate control module for a short-circuit to ground according to Short-circuit to ground, permanent faults .
- #B18 left-hand temperature damper motor
- #B19 right-hand temperature damper motor
- #B20 defroster damper motor
- #B21 recirculation damper motor
- #B22 floor / ventilation damper motor
Other information:
- To connect the breakout box, see Connecting the breakout box .
- To access / replace the climate control module, see Dashboard environment panel (including climate control module (CCM)), replacing .
- For the location of the damper motor connectors, see Location of components .
- For other values, see Signal description, climate control module (CCM), Connector A and Signal description, climate control module (CCM), Connector B .
- Continue
Refer to Self-adjustment