Checking the wiring
- Ignition off
- Disconnect connector B on the climate control module (CCM).
- Ignition on
Check the matrix wiring. Check for a short-circuit to supply voltage. Check for a short-circuit to ground.
Take readings between the following terminals on connector B and ground:
- #B11 (#11)
- #B12 (#12)
- #B13 (#13)
- #B14 (#14).
Check whether there is an internal short-circuit in the matrix cables. Take pairs of readings between all the terminals #B11-#B14 on connector B.
Other information:
Was a fault detected?
- YES
Refer to Equipment
- NO
Refer to Checking the component