Checking the connectors and wiring
- Ignition off
- Disconnect the connector for the climate control module (CCM).
Check the signal cable between the climate control module (CCM) and the evaporator temperature sensor. Check for a short-circuit to supply voltage.
Take a reading on the connector for the climate control module (CCM) between terminals #5 (#29) and #16 (#40).
Check the ground lead between the climate control module (CCM) and the evaporator temperature sensor. Check for a short-circuit to supply voltage.
Take a reading on the connector for the climate control module (CCM) between terminals #13 (#37) and #16 (#40).
The voltage must be approximately 0 V.
Check the signal and ground cables between the climate control module (CCM) and the evaporator temperature sensor. Check for an intermittent open-circuit.
Take a reading between terminals #5 (#29) and #13 (#37) on the connector for the climate control module (CCM).
Check the connectors for contact resistance and oxidation.
Remedy as necessary.
Other information:
- Continue
Refer to Information