LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 12 Of 12 >> Rem-8F61: Rear Window Defroster Relay. Signal Too High. Permanent Fault (1999-2004) >> Signal too high. Permanent fault >> Checking wiring and components

Checking wiring and components

Check the cable between rear electronic module terminal D1 (#B01) and "Rear windshield defroster" relay 2/82 terminal 2 for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .

Check the relay terminal, in particular relay guide 2/82 terminal 2, for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .

Remedy as necessary.

Try a new relay if no faults are found.

Other information: 

Fig 1: Identifying Voltage Display
GLL101041Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relays
GLL104089Courtesy of VOLVO CARS OF NORTH AMERICA.