Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 8 Of 12 >> CEM-8A08: Extra Lamp Relay. Signal Too High. Intermittent Fault (1999-2004) >> Signal too high/signal missing. Intermittent fault >> Checking the wire and relay

Checking the wire and relay

Check the wire between control unit 6C and relay 2/64 1 for an intermittent short circuit to voltage supply as described in Short-circuit to supply voltage, intermittent faults , contact resistance and oxidation as described in Contact resistance and oxidation and a loose connection as described in Loose connections (terminals) .

Also check the same connectors for an intermittent short circuit to voltage supply as described in Short-circuit to supply voltage, intermittent faults or for contact resistance and oxidation as described in Contact resistance and oxidation and for a loose connection as described in Loose connections (terminals) .

Check that relay 2/64 is installed correctly.

Do the necessary corrective action.

Additional information: 

Fig 1: Breakout Box
GLL100304Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Voltage Display
GLL101041Courtesy of VOLVO CARS OF NORTH AMERICA.