Checking the signal cable
- Ignition off
- Disconnect the connector from the central electronic module (CEM)
- Disconnect the immobilizer antenna unit.
Check the signal cable between central electronic module (CEM) connector terminal #13D and immobilizer antenna unit terminal #3. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access the central electronic module (CEM) connector, see Central electronic module (CEM), replacing
- To access the immobilizer antenna unit/connector, see Antenna unit, start inhibitor, replacing
- To connect the breakout box, see Connecting the breakout box
- For information about signals:
- -2004: see Signal specification
- 2005-: see Signal specification
- See Checking wiring and terminals .
Is the signal cable OK?
- YES
Refer to Replacing the component
- NO
Refer to Verification