LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 6 Of 12 >> CEM-5F43: Power Supply. Missing (2005-2006) >> Missing >> Intermittent fault

Intermittent fault

Check the combustion preheater module (CPM) connectors. Check for loose connections. Check for contact resistance and oxidation.

Check the circuit between combustion preheater module (CPM) terminal #11 and the components which are connected to the supply circuit (water pump terminal 2, fuel pump (FP) terminal 1 and combustion fan supply terminal). Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground.

Remedy as necessary.

Other information: 

Fig 1: Identifying Connector Terminals
GLL104183Courtesy of VOLVO CARS OF NORTH AMERICA.