LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 6 Of 12 >> CEM-5F42: Power Supply. Faulty (2005-2006) >> Faulty >> Intermittent fault

Intermittent fault

Check the circuit between combustion preheater module (CPM) terminal #11 and the components which are connected to the supply circuit (water pump terminal 2, fuel pump (FP) terminal 1 and combustion fan supply terminal). Check for an intermittent short-circuit to supply voltage.

With the ignition on and the water pump connector disconnected, the voltage between water pump terminal 1 (control module side) and ground should be approximately 0 V.

Remedy as necessary.

Other information: 

Fig 1: Identifying Connector Terminals
GLL104183Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohm Meter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 3: Breakout Box
GLL100304Courtesy of VOLVO CARS OF NORTH AMERICA.