Intermittent fault
Check the cable between control module terminal #13 and fuel pump (FP) terminal 2. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see Connecting the breakout box
- To access or replace the fuel pump (FP):
- For cars manufactured up to w38 2001 inclusive, see Fuel pump, auxiliary heater, replacing
- For cars manufactured from w39 2001 inclusive, see Fuel pump auxiliary heater, replacing .
- With the ignition on and the fuel pump (FP) connector disconnected, the voltage between fuel pump (FP) terminal 2 (control module side) and ground must be 0 V
- For other values, see Signal specification
- See Checking wiring and terminals
- Continue
Refer to Information