Intermittent fault

Check the electrical terminals on the combustion fan and the control module connector. Check for contact resistance and oxidation.

Check the cable between control module terminal #10 and the signal terminal for the combustion fan (the black lead from the fan). Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground.

Check the cable between control module terminal #11 and the voltage terminal for the combustion fan (the red cable from the fan). Check for an intermittent open-circuit.

Remedy as necessary.