Checking the connectors
- Ignition off
- Check the electrical terminals on the combustion fan and the control module connector. Check for contact resistance and oxidation and remedy.
Check for damage carefully
- Reinstall the components, reconnect the connectors etc.
- Ignition on
- Activate the combustion fan.
Listen for a buzzing sound which indicates that the combustion fan is running.
If the combustion fan now operates, the cause of the fault was loose connections in the connectors.
Other information:
- To access the control module or connect the breakout box, see Connecting the breakout box
- To access the combustion fan:
- For cars manufactured up to w38 2001 inclusive, see Fuel injection nozzle / fan motor / pressure equalizer, replacing
- For cars manufactured from w39 2001 inclusive, see Fuel injection nozzle / fan motor / pressure equalizer, replacing .
- See Checking wiring and terminals .
Does the combustion fan function?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to Checking components and wiring