Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 6 Of 12 >> CEM-5F3C: Combustion Fan. Signal Too High (2005-2006) >> Signal too high >> Checking components and wiring

Checking components and wiring

Check the cable between combustion preheater module (CPM) terminal #10 and the signal terminal for the combustion fan (the black lead from the fan). Check for a short-circuit to supply voltage.

The combustion fan must be replaced if no faults are found in the cable.

Remedy as necessary.

Other information 

Fig 1: Brake Pedal Position Sensor Connector Terminal Identification
GLL104085Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Connector Terminals
GLL104183Courtesy of VOLVO CARS OF NORTH AMERICA.


Check the cable between combustion preheater module (CPM) terminal #10 and the signal terminal for the combustion fan (the black lead from the fan). Check for an intermittent short-circuit to supply voltage.

Remedy as necessary.

Other information 

Fig 1: Brake Pedal Position Sensor Connector Terminal Identification
GLL104085Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Connector Terminals
GLL104183Courtesy of VOLVO CARS OF NORTH AMERICA.