Checking the generator (GEN) and battery
- Ignition off
- Connect the breakout box to the central electronic module (CEM)
- Start the engine.
Check the 30-supply to central electronic module (CEM) terminal #3E (breakout box terminal #B23) and terminal #6E (breakout box terminal #B26). The voltage must not exceed 15 volts at 2,000 RPM.
Also check that the battery is not over-charging.
Remedy as necessary.
Other information:
- To access the central electronic module (CEM), see Central electronic module (CEM), replacing
- To connect the breakout box, see Connecting the breakout box
- The generator (GEN) connector:
- For B5xx4x, -2004, see Generator (GEN), replacing .
- For B5xx4x, 2005-, see Generator (GEN), replacing .
- For B6xx4x, -2004, see Generator (GEN), replacing .
- For B6xx4x, 2005-, see Generator (GEN), replacing .
Was the function OK?
- YES
Refer to Verification
- NO
Refer to Replacing the component