Checking the connectors
- Ignition off.
Check central electronic module (CEM) connector for contact resistance and oxidation, as described in Contact resistance and oxidation .
Check especially for any damage.
HINT: If cause of fault is found, then install components, connect connectors etc. If cause of fault is not found do not install control unit until you have completed the trouble-shooting.
Additional information:
- To access central electronic module (CEM) connector see Central electronic module (CEM), replacing .
Is there a fault?
- YES
Refer to Verification
- NO
Refer to Checking the component and wire