Checking the component and wire
- Ignition off.
Check the wire between control unit 1B and ignition lock S for an open circuit as described in Open-circuit, permanent faults and for a short circuit to ground as described in Short-circuit to ground, permanent faults .
Additional information:
- The voltage should be the same as the battery voltage if the key is in position 0, I, II or III.
- To access/replace the CEM connector, see Central electronic module (CEM), replacing
- To connect the test box to the control unit, see Connecting the breakout box
- For further information about signals and other values:
- -2004: Signal specification
- 2005-: Signal specification
Is the voltage the same as the battery voltage?
- YES
Refer to Verification
- NO
Refer to Replacing the component