Checking the wiring and sensor
Check the wiring between pressure sensor 1 connection:
- #1 and control unit #28 (#A28)
- #2 and control unit #12 (#A12)
- #3 and control unit #43 (#A43)
for an intermittent open circuit as described in Open-circuit, intermittent faults , an intermittent short circuit to ground as described in Short-circuit to ground, intermittent faults , and an intermittent short circuit to voltage supply as described in Short-circuit to supply voltage, intermittent faults .
Do the necessary corrective action.
Additional information:
- To connect the test box, see Connecting the ABS/DSTC breakout box .
- For checking/replacement of the pressure sensor, see Pressure sensor, master cylinder, replacing .
- For information on signals, see Signal specification, ABS/DSTC (dynamic stability and traction control) control module .
- Continue
Refer to Information