Checking the wiring and component
Check the wiring between control module terminal #25 and the battery. Check for an open-circuit according to Open-circuit, permanent faults . Check for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Check that fuse 4 in the integrated relay/fusebox in the engine compartment is intact. If the fuse is blown, check the cable between the fuse and control module terminal #25 for a short-circuit to ground according to Short-circuit to ground, permanent faults and then replace the fuse.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the ABS breakout box .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the pump motor circuit