Checking Component And Cables
Check cable between control module #4 and flame trap ground terminal for an open-circuit according to Open-Circuit, Permanent Faults .
HINT: Because it is difficult to separate the flame sensor cables measure between control module #4 and both flame sensor cables.
Check cable between control module #8 and flame sensor signal terminal for an open-circuit according to Open-Circuit, Permanent Faults and a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
HINT: Because it is difficult to separate the flame sensor cables try to measure one flame sensor cable at a time and see if there is a relevant value on either of them.
If no fault is found in the connectors or cables, try a new flame sensor.
Remedy as necessary.
Other information:
- To access the control module/connect breakout box, see Connecting the Breakout Box .
- To access/replace the flame sensor, see Replacing Fuel Injection Nozzle, Fan Motor And Nozzle Pipe .
- With ignition on and flame sensor signal cable cut the voltage between flame sensor signal cable (engine control module (ECM) side) and ground should be approximately 5 V.
- For other values, see Signal Specification Additional heater 912-D/B .