LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2003 >> C70 2.3 53, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 74 (Climate Units - Specifications, Electrical/Electronic (Coupe)) >> Signal Description. Additional Heater (1999-2002) >> Signal Specification Additional Heater 912-D/B

Signal Specification Additional Heater 912-D/B

WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.

General 

All values given below are between the respective terminal in column 1 and terminal #3 (power ground) unless otherwise stated in brackets after the table entry. Control module terminals #1-#16 correspond to #1-#16 on the breakout box.

NOTE: It is important to connect the breakout box and check ground terminals before taking readings.
U= DC voltage in volts (V) UAC = AC voltage in volts (V)
Ubat = Battery voltage (V) f= Frequency in Hertz (Hz)
Ulow = Voltage approximately 0 V % duty= Duty cycle (pulse ratio) as a percentage (%)
t= Time in milliseconds (ms) - -
Terminal  Signal Type  Ignition On  Engine Idling  Remarks 
#1 Glow plug signal Glow plug off: U=Ulow
Glow plug on: Pulse ratio (% duty) 0%
Pulse ratio (% duty) increases with glow plug intensity.
#2 Control signal passenger compartment blower fan (when installed as accessory) No accessory installation: U≈0 V
Relay installed
Relay not activated: U≈12 V
Relay activated: U less than 2.5 V
-
#3 Power ground
Measured to battery negative terminal (-)
Ulow -
#4 Signal ground, outside temperature sensor, Coolant temperature sensor and flame sensor Ulow -
#5 Signal from generator (GEN) U < 2.75 V U > 7 V -
#6 Diagnostic lead, K-link U≈8.1 V U≈9.8 V If the fault tracing-instrument is connected the other values apply
#7 Outside temperature sensor signal +20°C: U≈0.5 V Voltage increases with decreasing temperature
#8 Flame sensor signal Flame not lit: U≈5 V
Flame lit: U<1.5 V
-
#9 30-supply (Power supply from battery) Ubat -
#10 Combustion fan control signal Combustion fan off and power supply off: Ulow
Combustion fan off and power supply on: Ubat
Fan on: Pulse ratio (% duty) 0%
The pulse ratio (% duty) increases with fan speed.
#11 Combustion fan, fuel pump and water pump power supply Power supply off: Ulow
Power supply on: Ubat
-
#12 Water pump control signal Water pump off and power supply off: Ulow
Water pump off and power supply on: Ubat
Water pump on and power supply on: Ulow
-
#13 Fuel pump control signal Fuel pump off: f=0 Hz
Fuel pump on: f>0 Hz
Frequency increases with pump speed
#14 Timer control signal Timer active: U > 7 V
Heater start after rest: U < 2.75 V
Remarks: 2.75 V < U < 7 V
-
#15 15-supply (power supply from ignition switch) Ubat Ubat -
#16 Coolant temperature sensor signal +20°C: U≈3.5 V Voltage decreases with increasing temperature