Intermittent Fault
WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.
Check cable between ECC control module #A26 and damper motor terminal 5 and ECC control module #A27 and damper motor terminal 4 for an intermittent open circuit according to Open-Circuit, Intermittent Faults and an intermittent short-circuit to ground according to Short-Circuit To Ground, Intermittent Faults and an intermittent short-circuit to supply voltage according to Short-Circuit To Supply Voltage, Intermittent Faults .
Other information
- To remove the control module, refer to Replacing ECC Control Module .
- To access/replace the recirculation damper motor, see Replacing Damper Motor Recirculation .
- To connect the breakout box, see Connection Of Breakout Box ECC .
- Voltage on cables should be less than 1 V or 2-4 V below battery voltage, depending on which direction the motor is turning in. When the damper motor is not activated the voltage should be approximately 0 V. For other values, see Signal Specification ECC .
- Continue