Checking Cables, Blower Fan Does Not Start
Check the ECC control module, blower fan power unit connectors for Contact Resistance And Oxidation . Check that connectors are connected correctly.
Check signal cable between ECC control module #A15 and power unit #A1 for an open-circuit according to Open-circuit, Permanent Faults and a short-circuit to ground according to Short-Circuit To Ground, Permanent Faults .
Check signal cable between ECC control module #A5 and power unit #A3 for an open-circuit according to Open-Circuit, Permanent Faults and a short-circuit to ground according to Short-Circuit To Ground, Permanent Faults .
Check power supply to blower fan for an open-circuit according to Open-Circuit, Permanent Faults .
Check ground lead between blower fan and power unit for an open-circuit according to Open-Circuit, Permanent Faults .
If cables are OK, try a new power unit.
Remedy as necessary.
Other information:
- To access/replace the control module, refer to Replacing ECC Control Module .
- To access/replace the power unit, refer to Replacing the Power Unit (Electronic Climate Control) .
- To access/replace the blower fan, refer to Replacing Blower Fan Motor .
- To connect the breakout box, see Connection Of Breakout Box ECC .
- For information on signals, refer to Signal Specification ECC .
- Continue
Refer to Verification