Home >> Volvo >> 2003 >> C70 2.3 53, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 91 (Electronic Climate Control (ECC), Manual Climate Control (MCC), Heater Module (HEA) - Diagnostic Trouble Code (DTC) Diagnostics - 1 Of 2 (Coupe)) >> ECC-411: Power Unit Blower Fan Motor (1998) >> Faulty Signal >> Checking Cables

Checking Cables

WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.

Check cable between ECC control module #A14 and power unit terminal #A2 for an open-circuit according to Open-Circuit, Permanent Faults , and for a short-circuit to ground according to Short-Circuit To Ground, Permanent Faults .

If cables are OK, try a new power unit.

Remedy as necessary.

Other information: 

Fig 1: Identifying 4-Pin Connector
GLL127461Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 3: Climate Control Module Connectors Terminals
GLL127471Courtesy of VOLVO CARS OF NORTH AMERICA.